ATS Designers Guide 67
Besides hardware compatibility, the user card compatibility needs to be ensured. The
ATS system supports many access card formats - see Table 4-19 – but not all of them
are supported by the control panel. The HID readers – see Table 4-13 – are compatible
with the HID access control cards in the ATS Wiegand 32 bit format – see Table 4-14.
Cards of this format are supported by the ATS1250/60 DGP, which means it’s sufficient
to program the card series for it to be active in the system. The control panel does not
support this format directly so for them to be connected directly to the system bus, the
IUM option of the ATS system needs to be used. This means that each card in the
system will have to be read during installation and stored in the user database.
Table 4-13 HID readers
Product Description
ACI730 Proximity card reader HID ProxPro Plus, range up to 20 cm, external
ACI755 Proximity card reader HID ProxPro, range up to 20 cm, external
ACI757 Proximity card reader HID ProxPro, range up to 20 cm, with keyboard
ACI760 Proximity card reader HID ProxPoint, range 5cm, low cost
ACI765P Proximity card reader HID MiniProx, range up to 10cm, miniature, external
ACI775 Proximity card reader HID MaxiProx, range 70 cm, waterproof, external
ACI795
Proximity card reader HID, range up to 14 cm, in flat housing, external .
(optional colour – white)
Table 4-14 HID cards
Product Description
ACT725-xx Proximity card for HID ProxCardII readers
ACT736-xx Dual card DuoProxII (magn.+ proximity HID), thin (ISO), printable
ACT745-xx ProxKeyII key fob, for HID readers
ACT786-xx Proximity card for HID ISO ProxII readers , thin (ISO), printable
ACT790-xx
Active proximity HID identifier (with battery) for vehicles, Dimensions: 10*7
cm
Table 4-15 Technical parameters of the HID readers.
HID Parameter ACI730 ACI755 ACI757 ACI760 ACI766 ACI775 795
Reader range 25cm 20cm 7,6cm 14cm 73cm 14cm
Keyboard - - Yes - - - -
Voltage 10-28,5VDC 5-16VDC 5-16VDC 12/24VDC 5-16VDC
Power cons. 100mA 100mA 30mA 20mA 200mA 20mA
Power cons., max. 120mA 120mA 75mA 110mA 1,2A 115mA
Dimensions 190x190x23 127x127x25 79,6x43,7x17
152x43x25
300x300x25 119x76x17
Housing Polycarbonates UL94
Operating temp. -30 – 65
o
C
Operating freq. 125kHz
Humidity 95%
4.5.2.2 MIFARE
MIFARE readers –Table 4-16 – are connected to the ATS system exactly like any other
Wiegand interface reader. (Ex. HID – see Drawing 4-6.) The offered readers are universal
multi-protocol devices, identifying the MIFARE cards (smart cards) by the serial number
of the card’s chip. Readers of this type – often called serial readers – are used to
integrate an existing installation, based on MIFARE smart cards, with the Advisor
MASTER system.