ATS Designers Guide 29
2.2 System equipment power consumption.
Devices equipped with a power supply – control panels, and some DGP – have safety
measures which prevent excessive battery discharging, switching them off if the voltage
drops below 10.5V. For other devices, the minimum voltage required to operate correctly
has been gathered in table Table 7-9 placed in the last chapter of the manual. The values
for equipment connected to devices equipped with a power supply are only for orientation
purposes.
Some devices have characteristic current consumption values depending on the
connected equipment. In the table below the current consumption is given for the device
with connected equipment. A detailed list of device parameters in different working
conditions are given in chapter 7 of the manual in table Table 7-9.
Table 2-4 Characteristic power requirements for the ATS devices.
Current con. mADevice
Connected
equipment
Description
Max. Average
ATS1100 - Keypad, 2*16 characters LCD/8 zone LEDs 185 73
ATS1105 -
Keypad, 2*16 characters LCD /8 zone LEDs with
Wiegand reader interface.
185 78
ATS1105+ ATS1410
ATS1105 manipulator with a magnetic card reader
connected
195 150
ATS1110 - Keypad, 2*16 characters LCD/16 zone LEDs 95 32
ATS1111 - Keypad, 4*16 characters LCD/16 zone LEDs 95 32
ATS1115 -
Keypad, 2*16 characters LCD/16 zone LEDs with inbuilt
ATS card reader.
165 86
ATS1116 -
Keypad, 2*16 characters LCD/16 zone LEDs with inbuilt
ATS card reader.
169 86
ATS1151 - LED keypad (3 diodes) in metal housing, no LCD
45 34
ATS1155 -
Outdoor, vandal-proof keypad (metal), 3 diodes,
detached electronics
70 70
ATS1156 -
LED Manipulator (3 diodes) in metal housing with
ATC600 magnetic card reader
45 39
ATS1170 - Wiegand reader interface (single door controller) – PCB 45 32
ATS1170+ ATS1190 Interface with a proximity card reader connected. 95 65
ATS1190 - Proximity reader (does not require an interface) 50 29
ATS1192 -
High resistance proximity reader (does not require an
interface) indoor/outdoor use
50 29
ATS1202 - 8 zones module for expander and control panel- PCB 10 9
ATS1210/11 - 8 zones and 8 outputs expander 53 50
ATS1210/11+ ATS1810 ATS1210 with 4 relay outputs module connected 130 70
ATS1210/11+ ATS1811 ATS1210 with 8 relay outputs module connected 225 110
ATS1210/11+ ATS1820
ATS1210 with 16 open collector outputs module
connected
90 38
ATS1220 - 4 zones and 8 outputs expander 53 45
ATS1230 - 433MHz wireless device receiver
39
ATS1290 - Point ID addressable sensor expander. 154 50
ATS1740 - Isolator/ RS485 bus repeater - PCB 90 60
ATS1741 - RS485 / RS232 bus converter- PCB 100 100
ATS1742 - RS485 bus loop interface – PCB 86 86
ATS1743 - Fibre-optical bus converter- PCB 60 36
ATS1810 - 4 relay NO/NC outputs module – PCB 60 1
ATS1811 - 8 relay NO/NC outputs module – PCB 170 20
ATS1820 - 16 open collector outputs module – PCB 50 20