52 ATS Designers Guide
The monitoring station has a direct connection to the control panels in the given
location.
One of the control panels is located in a separate building, connected only by
Ethernet wiring.
Beyond the premises (eg: another city) are two additional control panels, which
should be queried once a day, at a given time to synchronise the event log. One of
them doesn’t have access to a phone line.
The provided solution assumes communications between the PC monitoring station and
the local control panel using TCP/IP local network, and further along using the RS485
interface and bus accessories. The remote control panel can be accessed using the
Ethernet network, or connected directly. The control panels outside the premises can be
contacted by modem using a phone connection (for the control panel with phone line
access) and GSM connection (the control panel is equipped with the ATS7300 GSM
communicator for connecting to the monitoring station and the CS reporting station).
The provided solution requires the use of 3 branches/ports of the TITAN software. Note
that the maximum number of connections is 16 (older TITAN versions – 4 only).
If the remote location would require a service connection – programming, diagnostics
without event archival and system control – the modem can be left out and the inbuilt
communicator can be used. This solution is not advisable, as it doesn’t allow reporting
events to the CS station during the connection to a system monitoring station.
PC
TITAN
ATS
Control Panel
+
ATS1801
ATS1741
T
ATS1741
ATS
Control Panel
+
ATS1801
ATS1741
RS485
T
ACA300
ATS
Control Panel
+
ATS1801
MOD6000
RS232
ATS
Control Panel
+
ATS1801
ACA300
RS232
MOD6000
Ethernet*
PSTN
Leased line
GSM network
* -The TITAN software does not
support the TCP/IP protocol. It’s
necessary to install a serial port
emulator on the PC
ATS
Control Panel
+
ATS7300
Drawing3-17 Control panel network implementation diagram.
3.5 Reporting events to the CS station
Quick and effective reporting of events to several CS stations, using several
communication channels is essential for systems with higher levels of security. The ATS
system event reporting concept assumes availability of the same functions regardless of
the control panel type. Up to 4 independent CS stations can be programmed in the
Advisor MASTER system, each having 2 alternative phone numbers. The reporting can
work in two modes: