ATS Designers Guide 47
Table 3-12 List of ATS1230 DGP compatible transmitters.
Product Description Range m
RF320I4
Wireless magnetic sensor (or a transmitter for a wired
sensor – type NO/NC), sabotage
300
RF352I4 Remote control, keyfob 2 buttons 150
RF354I4 Remote control, keyfob 4 buttons 150
RF356I4 Wireless panic button in form of a wristwatch. 150
RF360I4
Water resistant wireless panic button, belt clip or neck
leash.
300
RF425I4
Wireless PIR sensor, EV425, 9/16m, 9 screens,
opening and tear-out sabotage alarm
300
RF425I4PI
Wireless PIR sensor, EV425, 9/16m, 9 screens,
opening and tear-out sabotage alarm, PI version
300
RF572NSTI4
Wireless optical-thermal smoke detector, sabotage
alarm, internal siren
300
RF620I4
Wireless inertia and magnetic sensor, sabotage alarm,
white
300
RF620I4B
Wireless inertia and magnetic sensor, sabotage alarm,
brown
300
RF903I4
Wireless glassbreak detector, acoustic, plaster
mounted, sabotage alarm
300
RF900I4 Diagnostic wireless sensor testing kit, 433MHz. 300
The device programming is very simple and consists of ”learning” the DGP all the
transmitters that it shall work with. The learning process consists of putting the DGP in
transmitter storing mode, and activating the devices in order, in which they should appear
in the system as alarm zones.
3.2.4 ATS1105 and ATS1170 RAS station reader interface
Both the RAS devices – ATS1105 and ATS1170 – have their own interface, for
connecting a Wiegand/Clock&Data standard compliant reader. The ATS1170 has the
reader type selectable by a DIP switch, and also can control the reader’s LEDs and
buzzer. Additionally it can locally store data for 20 cards in case of a loss of contact with
the superior unit.
The maximum distance form the reader to the controller is 70m – the wiring should be
done using UTP/FTP cat. 5 cables. Connection D0 and D1 within single pair of wires
should be avoided. It is recommended to pair the D0 and D1 signals with the ground.
3.3 PC connection.
A modern system, regardless of its complexity should offer an ability to connect to a PC.
The connection should enable communications with computer programs that provide
automated system maintenance, system programming, managing and monitoring etc.
This chapter summarises the basic information regarding the configuration of a PC
connection for communications with appropriate utilities.
3.3.1 Service connection
Each ATS control panel has a RS232 service connector (J18), which enables a direct
connection to a PC with the TITAN
®
software installed. This approach enables system
programming and maintenance without additional costs (required equipment in
Table 3-14), which is especially important in small systems, that do not require advanced
system monitoring functions. The connection has some limits: