DISARMING A SPLIT SYSTEM AS A BASIC OR STANDARD USER
If you enter the premises when the system is armed, the beeper will begin to beep with an intermittent tone to
indicate that the entry period has begun. During the beeping, you must not enter other areas of the system. If
you do, an alarm will be triggered. During this entry period you can disarm the system with your code. This
entry period has been programmed by the installer.
Because the system is split, you can select one or more areas from the available security areas.
1. The current status of the areas is shown in the display. Both
areas a fully armed.
[1] [2]
The entry period starts as soon as you open the entrance
door, or when you enter the entry zone. You can switch off
the system without activating the alarm as long as the
beeping continues. As soon as the beeping starts, the
display is illuminated.
Beep
Beep
2. Press the 0 key and then enter your code. A ‘*’ appears in
the display for every key you press. Use the 0 key to cancel
an incorrect entry.
Enter Code
0 + code
Enter Code ****
An underscore appears alternately under ‘1’ and ‘2’. Enter
the number of the area required.
[1] [2]
3. To disarm area 1, therefore, enter ‘1’.
1 2 3
4 5 7
7 8 9
0
1
Area 1 is automatically disarmed.
Disarm?
4. An underscore appears again alternating under ‘1’ and ‘2’ to
indicate that you can use an area. If you also want to disarm
area 2, enter ‘2’.
If there have been alarms or faults since the system was armed,
‘In Operator Log’ will appear instead of ‘1 [[2]]’. See also
‘Disarming after an alarm as a basic or standard user’ on 52.
1 [2]
Area 1 is disarmed and area 2 is still fully armed.
1 [2]